Extra Class Element 4 Effective 7/01/08-6/30/12
April 2, 2010Withdrawal of Questions from 2008 Element 4 Extra Class Question Pool.
The Question Pool Committee of the NCVEC is withdrawing questions E1C04 and E1C05 from the Extra pool effective July 1, 2010, although these may be removed by VEC’s immediately.
E1C04
E1C05
These two questions are being removed because the FCC has deleted rule 97.109(e) which is cited in these questions.
E1C04 (B) [97.109]
When may an automatically controlled station
retransmit third party communications?
A. Never
B. Only when transmitting RTTY or data emissions
although
these may be removed by VEC’s immediately.
These two questions are being removed because the
FCC has deleted rule 97.109(e) which is cited in these questions.
E1C04 (B) [97.109]
When may an automatically controlled station
retransmit third party communications?
A. Never
B. Only when transmitting RTTY or data emissions
------------
Extra Class - Element
4 Question Pool PDF Effective 7/01/08-6/30/12
Extra Class -Element
4 Question Pool MSWORD Effective 7/01/08-6/30/12
12 DIAGRAMS REQUIRED
A
revised and final release of the 2008 Element 4 (Extra Class)
question pool is hereby released for public use. This pool will
become effective for Element 4 examinations given on or after
July 1, 2008, and will remain active until June 30, 2012.
While every
effort was made to insure the accuracy of the material herein,
this material was prepared by ordinary human beings, and there is
always the possibility that a few typographical or other errors
may remain. Users are authorized to make whatever
typographic corrections that may be needed, keeping in mind that
the basic meaning of a question, answer, or distractor must
remain intact. The QPC would appreciate notification of any
such errors.
A list
of corrections and updates as of 02/20/2008 appear below. There
are 738 questions in the pool as released.
Whenever
possible, we have included references to the FCC rules for most
of the questions in section E1. The citations are included
only as a guideline, and while the QPC has made reasonable
efforts to insure accuracy, we do not guarantee that such
citations are accurate and/or complete.Any graphics required for
the questions are included at the end of this document, or are
available as a separate file from NCVEC.ORG To assist
in viewing fine details of some of the drawings associated with
certain questions, we recommend increasing the "zoom"
factor to 200% (or larger) when viewing the associated graphic.
Please refer any questions to the QPC, by e-mail, to QPC@NCVEC.ORG
Jim Wiley,
KL7CC
Chairman, NCVEC
Question Pool Committee
****Updates
and corrections to 2008 Extra class pool****
The
following corrections, deletions, and updates have been
incorporated in this version of the pool. Please use this version
for preparing exams and related materials.
The
following 8 questions were reported as having a problem by one or
more persons. However, after further review by the QPC,
these questions were determined to be correct as written:
E1C05
E1D01
E3B09
E4C08
E5C13
E6D01
E6D02
E7H05
The
following questions were edited or deleted:
E2B08
– missing "period" following "A"
in first distractor – corrected
E2E10
– this question was removed by the QPC – do not
renumber section
E5C14
– Correct answer "D" should read: "Polar
coordinates" instead of "Rectangular coordinates"
– corrected
E5D05
– answers "A" and "B" edited as follows:
A.
Electric current flow through the space around a permanent magnet
B. The region surrounding a magnet
through which a magnetic force acts
E7F07
inserted missing word "of" in second line of
question. Question now reads:
Which type of circuit would be a good choice for generating a series of harmonically related
receiver calibration signals?
E8C04
– this question was removed by the QPC – do not
renumber section
E9C16
– this question was removed by the QPC – do not
renumber section
E9E04
– typo in question number, shows as E90E04, corrected to
E9E04
E9H
– Sub-element title was incorrect. Correct version
should read as follows:
E9H Effective radiated power;
system gains and losses; radio direction finding antennas
E9H12
– typo in distractor "B" (remove word
"with", between "balanced" and
"against")
E0
– no section title. Correct section title reads as
follows:
SUBELEMENT E0 -- Safety [1 exam
question -- 1 group]
-------------------------------------------------------------------------------
Questions Withdrawn From
Use in the Current Amateur Radio Question Pools
Due to errors, omissions,
FCC Rule changes or other problems with original questions
released, the National Conference of VECs Question Pool Committee has formally withdrawn the following questions:
Extra Element 4 (Pool
Effective July 1, 2008- June 30, 2012)
E2E10
E8C04
E9C16
April 2, 2010Withdrawal of Questions from 2008 Element 4 Extra Class Question Pool.
E1C04
E1C05
|